The maintenance and overhaul of the flat mask machine is very important. The maintenance of the flat mask machine can bring better work, safer and higher efficiency to the mask machine, so what should we do when maintaining the flat mask machine?
The plane mask machine can be maintained according to the following aspects, and it is necessary to shut down the power supply during the maintenance process:
1. Ultrasonic system
Check whether the ultrasonic mask machine system is kept clean, especially the ultrasonic electric box, vibrator (transducer), and welding head must be dry and cleaned without water, and the connecting line must be firmly checked to check the wear of the ultrasonic welding head Please pay attention to the change of the pointer of the voltmeter and the ammeter on the ultrasonic electric box.
2. Pneumatic system:
The air filter cup of the mask equipment needs to be checked to see if there is any water discharge, and the air compressor should be discharged by the way, and the air compressor should be discharged every day in areas with high humidity, and check whether there is any air leakage in all the trachea cylinders. The cylinder magnetic anti-sensor Orientation and whether it is working properly.
3. Appearance
Masks are used to wear on the face, and medical masks need to enter the operating room. Therefore, the production of masks must require the clean cleaning of the mask machine equipment. After get off work every day, it is necessary to arrange personnel to clean the mask machine equipment after the shutdown and power failure. The work surface and the plate containing the mask should be cleaned. It should be noted that it cannot be cleaned with water, and the equipment should be cleaned with a non-toxic and volatile cleaning liquid such as alcohol.
Fourth, the electrical system
Check whether the connectors of the circuit of the mask machine equipment are loose, whether the main power cords, branch signal lines, etc. are worn out work etc.
5. Transmission system
The transmission system includes motors, gears, reducers, sprockets, chains, conveyor belts and other components. We need to check whether the motor has dust and other things attached to affect heat dissipation, and whether the gears and sprockets are oiled. If there are attachments, it should be Clean it up, whether the tightness of the chain is suitable or not, whether there are foreign objects that have not been cleaned, whether the connecting screws between the transmission parts are loose, whether the lubricating oil of the reducer is enough, usually the machine needs to replace the lubricating oil every 1000-1500 hours. .
6. Anti-rust
The equipment should not be stuck with corrosive liquids and objects. Sweat can easily cause the parts of the equipment to rust. If the equipment does not operate for a long time, it is necessary to apply anti-rust oil to the transmission system of the mask and the parts that are prone to rust.